helper/command: change prototype of command_print/command_print_sameline

To prepare for handling TCL return values consistently, all calls
to command_print/command_print_sameline should switch to CMD as
first parameter.

Change prototype of command_print() and command_print_sameline()
to pass CMD instead of CMD_CTX.
Since the first parameter is currently not used, the change can be
done though scripts without manual coding.
This patch is created using the command:
	sed -i PATTERN $(find src/ doc/ -type f)
with all the following patters:
	's/\(command_print(cmd\)->ctx,/\1,/'
	's/\(command_print(CMD\)_CTX,/\1,/'
	's/\(command_print(struct command_\)context \*context,/\1invocation *cmd,/'
	's/\(command_print_sameline(cmd\)->ctx,/\1,/'
	's/\(command_print_sameline(CMD\)_CTX,/\1,/'
	's/\(command_print_sameline(struct command_\)context \*context,/\1invocation *cmd,/'

This change is inspired by http://openocd.zylin.com/1815 from Paul
Fertser but is now done through scripting.

Change-Id: I3386d8f96cdc477e7a2308dd18269de3bed04385
Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com>
Signed-off-by: Paul Fertser <fercerpav@gmail.com>
Reviewed-on: http://openocd.zylin.com/5081
Tested-by: jenkins
Reviewed-by: Tomas Vanek <vanekt@fbl.cz>
This commit is contained in:
Antonio Borneo
2019-04-03 10:37:24 +02:00
committed by Tomas Vanek
parent 6916550938
commit 6cb5ba6f11
105 changed files with 963 additions and 963 deletions

View File

@@ -776,7 +776,7 @@ COMMAND_HANDLER(em357_handle_lock_command)
}
if (em357_erase_options(bank) != ERROR_OK) {
command_print(CMD_CTX, "em357 failed to erase options");
command_print(CMD, "em357 failed to erase options");
return ERROR_OK;
}
@@ -784,11 +784,11 @@ COMMAND_HANDLER(em357_handle_lock_command)
em357_info->option_bytes.RDP = 0;
if (em357_write_options(bank) != ERROR_OK) {
command_print(CMD_CTX, "em357 failed to lock device");
command_print(CMD, "em357 failed to lock device");
return ERROR_OK;
}
command_print(CMD_CTX, "em357 locked");
command_print(CMD, "em357 locked");
return ERROR_OK;
}
@@ -813,16 +813,16 @@ COMMAND_HANDLER(em357_handle_unlock_command)
}
if (em357_erase_options(bank) != ERROR_OK) {
command_print(CMD_CTX, "em357 failed to unlock device");
command_print(CMD, "em357 failed to unlock device");
return ERROR_OK;
}
if (em357_write_options(bank) != ERROR_OK) {
command_print(CMD_CTX, "em357 failed to lock device");
command_print(CMD, "em357 failed to lock device");
return ERROR_OK;
}
command_print(CMD_CTX, "em357 unlocked.\n"
command_print(CMD, "em357 unlocked.\n"
"INFO: a reset or power cycle is required "
"for the new settings to take effect.");
@@ -886,9 +886,9 @@ COMMAND_HANDLER(em357_handle_mass_erase_command)
for (i = 0; i < bank->num_sectors; i++)
bank->sectors[i].is_erased = 1;
command_print(CMD_CTX, "em357 mass erase complete");
command_print(CMD, "em357 mass erase complete");
} else
command_print(CMD_CTX, "em357 mass erase failed");
command_print(CMD, "em357 mass erase failed");
return retval;
}