helper/command: change prototype of command_print/command_print_sameline

To prepare for handling TCL return values consistently, all calls
to command_print/command_print_sameline should switch to CMD as
first parameter.

Change prototype of command_print() and command_print_sameline()
to pass CMD instead of CMD_CTX.
Since the first parameter is currently not used, the change can be
done though scripts without manual coding.
This patch is created using the command:
	sed -i PATTERN $(find src/ doc/ -type f)
with all the following patters:
	's/\(command_print(cmd\)->ctx,/\1,/'
	's/\(command_print(CMD\)_CTX,/\1,/'
	's/\(command_print(struct command_\)context \*context,/\1invocation *cmd,/'
	's/\(command_print_sameline(cmd\)->ctx,/\1,/'
	's/\(command_print_sameline(CMD\)_CTX,/\1,/'
	's/\(command_print_sameline(struct command_\)context \*context,/\1invocation *cmd,/'

This change is inspired by http://openocd.zylin.com/1815 from Paul
Fertser but is now done through scripting.

Change-Id: I3386d8f96cdc477e7a2308dd18269de3bed04385
Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com>
Signed-off-by: Paul Fertser <fercerpav@gmail.com>
Reviewed-on: http://openocd.zylin.com/5081
Tested-by: jenkins
Reviewed-by: Tomas Vanek <vanekt@fbl.cz>
This commit is contained in:
Antonio Borneo
2019-04-03 10:37:24 +02:00
committed by Tomas Vanek
parent 6916550938
commit 6cb5ba6f11
105 changed files with 963 additions and 963 deletions

View File

@@ -1579,11 +1579,11 @@ COMMAND_HANDLER(lpc2000_handle_part_id_command)
int status_code = get_lpc2000_part_id(bank, &part_id);
if (status_code != 0x0) {
if (status_code == ERROR_FLASH_OPERATION_FAILED) {
command_print(CMD_CTX, "no sufficient working area specified, can't access LPC2000 IAP interface");
command_print(CMD, "no sufficient working area specified, can't access LPC2000 IAP interface");
} else
command_print(CMD_CTX, "lpc2000 IAP returned status code %i", status_code);
command_print(CMD, "lpc2000 IAP returned status code %i", status_code);
} else
command_print(CMD_CTX, "lpc2000 part id: 0x%8.8" PRIx32, part_id);
command_print(CMD, "lpc2000 part id: 0x%8.8" PRIx32, part_id);
return retval;
}