contrib/firmware: add new i2c bit-banging feature to angie's firmware

add new i2c bit-banging feature, we can now connect in JTAG with the SoC
target and in i2c with the main board components at the same time.

Change-Id: I8e4516fe1ad5238e0373444f1c3c9bc0814d0f52
Signed-off-by: Ahmed BOUDJELIDA <aboudjelida@nanoxplore.com>
Reviewed-on: https://review.openocd.org/c/openocd/+/7796
Tested-by: jenkins
Reviewed-by: Antonio Borneo <borneo.antonio@gmail.com>
This commit is contained in:
Ahmed BOUDJELIDA
2023-08-16 17:05:05 +02:00
committed by Antonio Borneo
parent aa0056d273
commit aee495e785
14 changed files with 534 additions and 139 deletions

View File

@@ -1,13 +1,13 @@
# SPDX-License-Identifier: GPL-2.0-or-later OR GFDL-1.2-no-invariants-or-later
Bus 001 Device 056: ID 584e:424e NanoXplore, SAS. ANGIE Adapter
Bus 001 Device 029: ID 584e:424e NanoXplore, SAS. ANGIE Adapter
Device Descriptor:
bLength 18
bDescriptorType 1
bcdUSB 2.00
bDeviceClass 255 Vendor Specific Class
bDeviceSubClass 255 Vendor Specific Subclass
bDeviceProtocol 255 Vendor Specific Protocol
bDeviceClass 239 Miscellaneous Device
bDeviceSubClass 2
bDeviceProtocol 1 Interface Association
bMaxPacketSize0 64
idVendor 0x584e
idProduct 0x424e
@@ -19,13 +19,22 @@ Device Descriptor:
Configuration Descriptor:
bLength 9
bDescriptorType 2
wTotalLength 0x0027
bNumInterfaces 1
wTotalLength 0x0047
bNumInterfaces 2
bConfigurationValue 1
iConfiguration 4 (error)
iConfiguration 1 NanoXplore, SAS.
bmAttributes 0x80
(Bus Powered)
MaxPower 100mA
Interface Association:
bLength 8
bDescriptorType 11
bFirstInterface 1
bInterfaceCount 2
bFunctionClass 2 Communications
bFunctionSubClass 0
bFunctionProtocol 0
iFunction 0
Interface Descriptor:
bLength 9
bDescriptorType 4
@@ -33,9 +42,9 @@ Device Descriptor:
bAlternateSetting 0
bNumEndpoints 3
bInterfaceClass 255 Vendor Specific Class
bInterfaceSubClass 255 Vendor Specific Subclass
bInterfaceProtocol 255 Vendor Specific Protocol
iInterface 0
bInterfaceSubClass 0
bInterfaceProtocol 0
iInterface 4 JTAG Adapter
Endpoint Descriptor:
bLength 7
bDescriptorType 5
@@ -66,3 +75,33 @@ Device Descriptor:
Usage Type Data
wMaxPacketSize 0x0200 1x 512 bytes
bInterval 0
Interface Descriptor:
bLength 9
bDescriptorType 4
bInterfaceNumber 1
bAlternateSetting 0
bNumEndpoints 2
bInterfaceClass 10 CDC Data
bInterfaceSubClass 0
bInterfaceProtocol 0
iInterface 0
Endpoint Descriptor:
bLength 7
bDescriptorType 5
bEndpointAddress 0x06 EP 6 OUT
bmAttributes 2
Transfer Type Bulk
Synch Type None
Usage Type Data
wMaxPacketSize 0x0200 1x 512 bytes
bInterval 0
Endpoint Descriptor:
bLength 7
bDescriptorType 5
bEndpointAddress 0x88 EP 8 IN
bmAttributes 2
Transfer Type Bulk
Synch Type None
Usage Type Data
wMaxPacketSize 0x0200 1x 512 bytes
bInterval 0