Bug: Edimax BLE Dongle Fails After Teardown and Re-Instantiation

This patch addresses an issue where the some RTK BLE dongles fail to perform
an HCI reset after the transport is torn down and re-instantiated. To address
that, we prevent crashing the background threads when invalid data comes in,
and time out if no response is received within a fixed amount of time. When
the timeout occurs, we retry the reset, and ultimately skip over reading the
local version information if that fails.
This commit is contained in:
Ford Peprah
2024-08-14 13:58:02 -04:00
parent ac0cff43b6
commit aa658418bc
2 changed files with 29 additions and 9 deletions

View File

@@ -301,6 +301,8 @@ class Driver(common.Driver):
fw_name: str = ""
config_name: str = ""
POST_RESET_DELAY: float = 0.2
DRIVER_INFOS = [
# 8723A
DriverInfo(
@@ -495,12 +497,22 @@ class Driver(common.Driver):
@classmethod
async def driver_info_for_host(cls, host):
await host.send_command(HCI_Reset_Command(), check_result=True)
host.ready = True # Needed to let the host know the controller is ready.
try:
await host.send_command(
HCI_Reset_Command(), check_result=True, response_timeout=cls.POST_RESET_DELAY
)
host.ready = True # Needed to let the host know the controller is ready.
except asyncio.exceptions.TimeoutError:
logger.warning("timeout waiting for hci reset, retrying")
await host.send_command(HCI_Reset_Command(), check_result=True)
host.ready = True
command = HCI_Read_Local_Version_Information_Command()
response = await host.send_command(command, check_result=True)
if response.command_opcode != command.op_code:
logger.error("failed to probe local version information")
return None
response = await host.send_command(
HCI_Read_Local_Version_Information_Command(), check_result=True
)
local_version = response.return_parameters
logger.debug(